| TB 11-5821-333-10-2
PRIMARY TASK 1: Load Single Channel Frequencies in SINCGARS RT
CONTROLS
ACTION
RESULT*
(1) Obtain proper
(Load CUE freq
freqs from ANCD**
only if directed)***
(2) Set RT controls:
MODE to SC
FCTN to LD
PRESET to MAN,
RT display shows
CUE, or 1-6
[30000](MAN) or
[Fill X] (1-6)
(3) Press:
FREQ
Display shows
[00000/30000]
CLR
Display shows
[_ _ _ _ _]
XXXXX (Freq)
Display shows freq
entered
STO
Display blinks (data
is stored)
(4) Repeat (3)
directed by
above for each freq
NCS or unit SOP)
(5) Set:
Loading of SC freqs
FCTN to SQ ON
is complete
*
ANCD display is shown as a dark bordered box. RT messages state "Display shows,' without dark border.
**
In unit using FH net, operators normally load only a MAN frequency on a routine basis. A CUE and SC
frequencies for CHAN 1-6 are loaded only as needed.
***
Only NCS and Alt NCS routinely load a CUE frequency.