| TB 11-5820-890-12
STEP 1
Remove the battery cover (3) by loosening the four captive screws (2).
STEP 2
Remove the battery housing (1) from the ANCD housing by inserting screwdriver under the extension lip (4)
and prying up.
STEP 3
Remove and replace the three batteries (5) by pushing the back three slots (6) of the battery housing;
observe the polarities of the batteries. The ANCD will not power up with the batteries reversed in the holder.
STEP 4
Insert the housing (1) into the ANCD with the positive contacts going into the housing slot.
STEP 5
Install the battery cover (3); tighten the four screws (2).
STEP 6
Turn the ANCD on to verify a successful battery change. Press "S' for SETUP. Press 'B' to go into Battery
Menu. Press 'LOCK LETTER" then "I' key and press 'ENTER".
b.
Initialization of the ANCD must be performed when:
1.
A Destructive BIT is run.
2.
The ANCD is zeroized.
3.
Batteries are installed after two minutes and the data is lost.
4.
When a new CIK is installed.
c.
The following are procedures describing the initialization procedures:
Go to "MAIN" Menu
Appl
Date Time Setup
Utll
Bit
Enter "UTIL"
Audit
Load Erase Format
CIK
Ckdat Revno
Enter "CIK"
Itclk
Lddik
Enter "Itcik"
Enter CIK Serial Number
Enter "1"
Enter CIK Index [1...8]
Enter "'1"
Please Stand By
Within six seconds, press
Press [ENTRI until
'ENTR" button until prompted
requested to stop
to stop. (Approximately 32
'ENTR' will be required.)