Switch Settings and Initialization. The following table provides the necessary switch settings and
6.
communication parameters for interoperability. Verify the switch settings for the radio. The Communications
Data selections in the AN/TPQ-36 do not change from those normally selected when using the VRC-12 family
radios.
Table 6-1. SINCGARS Radio Set
7.
System Troubleshooting Procedures. These steps will assist you in is dating faulty system components when
you have a problem communicating in a net using data transmission. These procedures assume that the net
and secure FH voice communication has been established. If you are unable to communicate using data
transmission, do the following troubleshooting steps in the order provided.
CHECK LOCAL RADIO. Use the data on the FH voice net to determine that the radio net is
operating.
CHECK WITH OTHER NET MEMBERS. Do you have data communication with some stations but
not others? The other station may be out of range, temporarily off the air, or has not checked into the
net. If data communication can be established with another station, your system is probably OK and
the problem may be at the distant net station.
CHECK SYSTEM CONFIGURATION. Verify proper cabling, initialization and subscriber parameters,
radio set and AN/TPQ-36 switch settings, etc.
NOTIFY MAINTENANCE. If the problem cannot be isolated, notify unit maintenance personnel and
inform your NCS of your communication problem.