Page Title: Table 1. Radio Set Electrical Test-continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 



MWO 11-5821-260-30-1Text
Table 1. Radio Set Electrical Test -- Continued
Equipment under test
Test equipment
Step
Performance standard
Test procedure
control settings
control settings
No.
A. Set the radio set
A. None.
Same as step 1.
Same as step 1.
11
function switch to
D/F and squelch
switch to ON. Adjust
am. generator for the
following output
signal applied to
maintenance kit
connector J12:
116.000 MHz
Amplitude:
100 Vrms
Modulation:
1 kHz, 90%
B. Observe the homing
B. The homing on-off indicator
on-off indicator in
indicates all black.
the lower left-hand
corner of main-
tenance kit
HOMING/ADF/
GYRO indicator.
20