| MWO 11-5821-260-30-1
Table 1. Radio Set Electrical Test -- Continued
Equipment under test
Test equipment
Step
Performance standard
Test procedure
control settings
control settings
No.
A. None.
A. Set the maintenance
Same as step 1.
4
Same as step 1.
kit RADIO TEST
switch to position 2
and set the radio set
function switch to
RETRAN. Adjust
the am. generator
for the following
output to main-
tenance kit connec-
tor J12:
116.000 MHz
Amplitude:
100 Vrms
Modulation:
1 kHz, 90%
B. Adjust the AUDIO
B. Radio audio output is 2.75 Vrms.
control until the radio
audio output at
maintenance kit con-
nector J18 is 2.75
Vrms.
C. Observe the main-
C. The CONTROL SIGNAL lamp
tenance kit
lights.
CONTROL SIG-
NAL lamp.
D. Remove cable from
D. The CONTROL SIGNAL lamp
maintenance kit con-
is out.
nector J12.
13
|