  | ![]() TM 11-5895-1141-34 
Table 4-16. MODULE TEST SET, JACK PANEL TEST 
Step 
Operation 
Normal Indication 
1 
All module test set controls must he preset 
according to the procedure in 
paragraph 4-10. 
2 
Using the cables provided, hook up the jack 
panel test set. 
a. Connect the twin plug cable between the 
INSTR jacks on the test set and the HEADSET 
jacks on the jack panel. 
b. Connect the jack panel cable plug to 
socket J10 on the test set. 
3 
Set the METER SCALE switch to the 0.35 v/ 
-10 dB position; set the 600 Q DUMMY LOAD 
switch to the OUT position; set the CONTR- 
INSTR switch to the INSTR position and 
adjust the OSCILLATOR LEVEL to 0.18 volt. 
This results in -11 dBm input at 50 ohms to 
the jack panel. 
4 
Set the OUTPUT SELECT switch to XMTR AUDIO; 
A meter reading the same as in table 4-11, 
set the LOCK/NONLOCK switch on the selector 
step 5 should be obtained. After taking the 
module to the LOCK position. Turn the P/T 
meter reading turn the P/T switch to OFF. 
KEY switch to ON. 
4-46 
 | 
| 
 