TM  11-5820-890-20-2 2-33 2.2. TROUBLESHOOTING FLOWCHARTS. Continued Chart 5 AM 1780 RELAYS DO NOT CLICK AND SIDETONE NOT HEARD. AM 1780 WILL NOT KEY FROM A SPECIFIED CONTROL BOX. (Sheet 1 of 3) V U T S R P N M L K J H F E D C B A AM 1780 J504, J505, J506, J507 P N M L B C D E F G H J K A NO YES AM 1780 WILL NOT KEY FROM CX 2297 ? 2 SH 2 1.   FROM CONTROL BOX AM 1780 WILL NOT KEY, REMOVE CX 4723/7060 FROM AM 1780 J504, J505, J506, OR J507. 2.   MEASURE VOLTAGE AT CONNECTOR J504, J505, J506, OR J507 PIN H TO PIN A (GND). 1 SH 2 NO YES 22 TO 32 V dc ? REPLACE AM 1780. 1.   CONNECT CX 7060 TO AM 1780. 2.   REMOVE CX 7060 FROM HULL BENDIX CONNECTOR. 3.   MEASURE VOLTAGE AT HULL BENDIX CONNECTOR, PIN M TO PIN N (GND). START HULL BENDIX CONNECTOR NO YES 22 TO 32 V dc ? 3 SH 3