3-20.1 Removal and Replacement of Air Filters
T-1054/GRC-144 is equipped with three air filters, as is
equipment R-1467/GRC-144. Two air filters are located
inside the electrical equipment cabinet (1A15 or 2A15),
one on each of the two doors (Fig. 3-1,3-3.1). A third
filter is mounted on top of the cabinet.
a. Door Mounted Air Filters To remove or replace a
door mounted air filter proceed as follows:
(1) Lift and turn the three cabinet door latch
handles and open the two cabinet doors.
(2) If the air filter is seated in a retaining frame
merely slide the filter upward and remove from the frame
If the filter is retained by six captive screws, first loosen
the screws and then slide the filter upward to remove (Fig.
(3) If the air filter is to be cleaned, use a
solution of water and detergent Allow to dry before
replacing (4) Insert cleaned or replacement filter Into the
retaining frame If the filter is retained by six captive
Figure 3-3.1. Door mounted air filter removal.
screws, tighten the screws loosened in (2) (5) Close and
latch the two cabinet doors.
b. Cabinet Mounted Air Filters To remove or replace
the air filter mounted on top of the electrical equipment
cabinet 1A15 (Fig 3-7) or 2A15 (Fig 3-20) proceed as
follows.
(1) Set POWER ON-OFF switch on the meter
panel assembly 1A15A8 or 2A15A2 to OFF.
(2) Loosen lint, do not remove the facer air
filter screws securing the air filter to the top of the
electrical equipment cabinet.
(3) Remove air filter.
(4) If the filter is to be cleaned, use a solution
of water and detergent. Allow to dry before replacing.
(5) Place the cleaned or replacement filter on
top of the electrical equipment cabinet, aligning the four
screw holes. Tighten the screws.
Change 5 3-34.1