TM 11-5820-554-12
Output regulation:
7-20. Tabulated Data
Low voltage.................. 290 volts maximum at 170 ma.
Input requirements:
.................................... 265 volts minimum at 210 amperes.
Voltage .........................
11 to 16 volts nominal.
High voltage................. 870 volts maximum at 55 ma.
Current ........................
Up to 30 amperes.
.................................... 695 volts minimum at 230 ma.
Outputs (nominal)
Ripple present on outputs:
Heater...........................
12 volts, 6.0 amperes.
Bias ............................. Less than 0.35 volt peak to peak.
Bias ..............................
-50 to -80 volts
Low B+ ........................ Less than 0.2 volt peak to peak.
adjustable (47,000 ohm
High B+ ....................... Less than 10 volts peak to peak.
load).
Efficiency ............................ Approximately 80%.
Low B+ ........................
265 volts, 210 ma.
Operating temperature ......... -30C. to +60C.
High B + ......................
750 volts, 185 ma.
Humidity ............................. 0 to 95% at +50' C. for 48 hours
7-21. Items Comprising Power Supply 12-Volt D.c. Input
Dimensions
Weight
NSN
Item
Qty
Height
Depth
Width
(lb)
5820 00-034 4233
Power supply 12-volt d.c. input (Collins MP-1)
1
3 3/4
5 1/4
11
7 1/2
No. 10 solder lugs
5
No. 6 solder lugs
5
Cable clamp
1
Sheet metal screws No. 12 x 1
4
30-ampere fuses
1
with No. 10 lugs (furnished). If the Collins 351D-2 is
7-22. Installation
not used, procure the necessary wire and connect the
a. Select a location in the car for mounting the
car power supply to the studs on the Collins MP-1. If
(Collins MP-1 where it will be cool, clean, and dry as
necessary, the cable may be secured by one of the
possible. Location under the seat or on the passenger
mounting screws and the cable clamp furnished.
side of the fire wall is satisfactory. The sheet-metal
CAUTION
screws supplied require 5/32-inch mounting holes. The
The Collins MP-1 is connected for
shortest possible length of line to the battery is
negative ground when shipped from the
desirable. Under full load, the Collins MP-1 draws
factory. Observe proper polarity or the
approximately 25 amperes.  At these current levels,
Collins MP-1 will not operate. See figure
voltage drop through unnecessarily long leads can be
7 for stud strapping details. Be sure to
appreciable.
Coupled with normal variations in
reverse the yellow and blue connections to
primary voltage due to fluctuations in generator
stud-mounted diode CR1 if positive
charging rate, this will have an adverse effect upon the
ground is to be used.
Collins MP-1 output voltage regulation.
7-23. Initial Checks
b. Determine the necessary length of power cable to
Turn the Collins KWM-2/2A MIC GAIN control fully
connect the Collins MP-1 to the equipment which it is
counterclockwise (off) until the switch clicks. Set the
to operate. If the power supply is to provide voltages
OFF-ON-NB-CAL switch to ON. Set the meter switch
for the Collins KWM-2/2A and the Collins 351D-2, cut
to PLATE and the EMISSION switch to LOCK. The
the required length of cable from the cable furnished
transceiver is in the receive condition during warm-up,
with the mount. Attach the necessary solder lugs to the
so the meter will read full scale until the filaments reach
loose end of the cable for connection to the terminal
operating temperature. This is normal S-meter action.
board of the Collins MP-1.  Five No. 6 lugs are
When the S-meter falls back to a lower value, the
supplied with the power supply (para 7-21). Figure 7-8
circuits will have switched to transmit condition, and
shows proper power supply interconnections to the
the meter will indicate pa plate current. Read the no-
Collins KWM-2/2A and 351D-2 combinations.
signal plate current. It should be approximately 40 ma.
c. Remove the cover from the Collins MP-1, and
If the plate current is other than 40 ma, adjust bias
make connections to the terminal board (fig. 7-8). Two
adjust potentiometer R11 on the power supply printed
lengths of No. 10 wire are furnished with the Collins
circuit board to set the plate cur
351D-2 for connection between the power supply and
battery. Cut these wires to the required length, and fit